IMPORTANT!
PLEASE READ THIS BEFORE INSTALLATION.
This thermostat is tested and certified by Pepper One Gmbh
according to the requirements put forward by the Z-Wave
Alliance. This is a Z-wave Plus product with the 500 series chip.
If the product does not work with your gateway, then the
gateway manufacturer has not made an integration or
implemented such a thermostat with their gateway.
We do not give any guarantee towards integration.
PRINCIPLES FOR REGULATION
The Heatit Z-Wave thermostat is designed for controlling
electrical heating cables and electrical radiators/convectors.
The thermostat has 2 internal temperature sensors and has
3 algorithms for temperature compensation. After you have
set the temperature, the thermostat will use a hysteresis to
regulate the temperature. The hysteresis is adjustable.
TEMPERATURE SHOWN IN DISPLAY
The temperature shown in the display is the actual temperature
for floor sensor and the external room sensor. You are able to
calibrate the sensor values.
When using the internal room sensor, the temperature shown
is the set point. When using the internal sensor, the thermostat
can seem somewhat inaccurate. This is due to heat generation
inside the thermostat, draft and other external influences.
If the thermostat is to be used with waterbased heating systems,
you have to use an external sensor.
SETUP
This manual describes the most essential functions and
technical specifications of the thermostat. These instructions
help the user to control the thermostat, and the electrician
to install and setup the thermostat.
INSTALLATION
Installation must be done by a qualified electrical installer in
accordance with the National Building codes. Before installation,
disconnect any power to the thermostat’s mains. During
installation of the thermostat, power to the thermostat must
be disconnected AT ALL TIMES!
Use e.g. a small slotted screwdriver. Start by carefully removing
the front cover by pushing the release springs. The front cover
and the frame can now be removed.
Now connect the wires to the thermostat’s terminals:
HEATING (N) Heating cable connection (Neutral)
N Power connection (Neutral) 230V
L Power connection (Live) 230V
HEATING (L) Heating cable connection (Live)
PILOT Pilot signal (ECO temp) 230V
FLOOR SENSOR NTC type (10, 12, 15, 22, 33 or 47kΩ).
Default 10kΩ.
EXTERNAL SENSOR NTC type (10, 12, 15, 22, 33 or 47kΩ).
Default 10kΩ.
Next, position the thermostat and fasten it onto the wall’s
mounting box using 2-4 screws. Position the frame, then
position and carefully press the front cover until it snaps in
place. Check that the front cover has snapped in place properly
on both left and right side. The front cover should now be firmly
fixed on all sides.
STARTUP
AFTER CONNECTING THE POWER TO THE THERMOSTAT FOR THE
FIRST TIME, ALL PARAMETERS WILL HAVE DEFAULT SETTINGS.
2 yr

HEATIT

Z-WAVE

Installers manual

Firmware 1.8
01.06.2016
Release spring
1: Left 3: Right2: Center
87 mm
58,8 mm
HEATING L
L
N
HEATING N
PILOT WIRE
FLOOR
SENSOR
EXTERNAL
SENSOR
Made in EU
TF 021
21,3 mm
51,1 mm
87 mm
58,8 mm
29,9 mm
Heatit HEAE5430498-B

Ho bisogno di aiuto?

Numero di domande: 0

Hai domande sul Heatit HEAE5430498-B o hai bisogno di aiuto? Fai qui la tua domanda. Fornisci una descrizione chiara e completa del problema e della domanda. Più dettagli fornisci per il tuo problema e la tua domanda, più facile sarà per gli altri proprietari di Heatit HEAE5430498-B rispondere correttamente alla tua domanda.

Consulta qui gratuitamente il manuale per il Heatit HEAE5430498-B. Il manuale rientra nella categoria Termostato ed è stato valutato da 1 persone con una media di 7.5. Il manuale è disponibile nelle seguenti lingue: Inglese. Hai domande sul Heatit HEAE5430498-B o hai bisogno di aiuto? Fai la tua domanda qui

Specifiche Heatit HEAE5430498-B

Generale
Marca Heatit
Modello HEAE5430498-B
Prodotto Termostati
EAN 7071236011927
Lingua Inglese
Tipo di file PDF
Caratteristiche
Termostato intelligente -
Funzione memoria No
Interfaccia Z-Wave
Colore del prodotto Nero
Unità di misura °C
5 - 40 °C
Codice di protezione internazionale (IP) IP21
Display
Tipologia display LCD
Contenuto dell'imballo
Telecomando portatile No
Gestione energetica
Capacità massima di interruzione 3600 W
16 A
Alimentazione AC
Tensione di esercizio 230 V
Condizioni ambientali
Intervallo di controllo della temperatura 0 - 25 °C
Altre caratteristiche
Corrente 16 A
Mostra di più