Smart Color Touchscreen Programmable ThermostatRTH9585WFSearch for local rebates: HoneywellHome.com/Rebates
Install your thermostat.
Connect your home Wi-Fi network.
Register online for remote access.
1
2
3
Welcome
Getting set up and ready is simple. Read before installing.
This thermostat works with common 24 volt
systems such as forced air, hydronic, heat
pump, oil, gas, and electric. It will not
work with millivolt systems, such as a gas
fireplace, or with 120/240 volt systems such
as baseboard electric heat.
1.1 Switch OFF power to your heating/cooling system
1.1a Important! To protect your
equipment, switch OFF the
power to your heating/
cooling system at the
breaker box or the system
switch.
1.1b Confirm power is OFF.
Try to turn on heating/
cooling equipment by
changing temperature
on your old thermostat.
Your power is OFF if your
system does not turn ON.
Install your thermostat
1
Circuit
breaker
box
Heating/
cooling system
power switch
C
M33823A
Terminal designation
If you have an older thermostat with a
sealed mercury tube, see warning page
for proper disposal instructions.
1.2 Remove old thermostat faceplate and leave wires connected 1.2a Take a picture of the wire connections for later reference. 1.2b If no wire is connected to a terminal labeled C or no C terminal exists on the old thermostat, view the Alternate Wiring videos at wifithermostat.com/videos
Important! C wire is required
and is the power source for your
thermostat. Without a C
wire, your thermostat will
not power up.
1.3 Label wires Do not label by wire color.
Use the supplied sticky tags to label
each wire as you disconnect it. Label
wires according to old thermostat
terminal designations, not by wire
color.
Note: If no tag matches a terminal
designation, write the appropriate
letter on a blank sticky tag.
Note: Wrap the wires around a pencil
to prevent them from falling back into
the wall.
1.4 Remove wallplate
Remove the old wallplate from
the wall after all wires are
labeled and disconnected.
Blank tagsSticky tagTerminal designation
M31537
C
C
M31545
1.5 Mount wallplate for thermostat
Mount your new wallplate using
screws and anchors included
with the thermostat.
If necessary:
Drill 3/16-in holes for drywall
Drill 7/32-in holes for plaster
Note: You may be able to use
your existing wall anchors. Hold
the wallplate up to the existing
anchors to check for alignment.
M34499
LEVEL
HERE
R
Y
C
W
G
C
K
Rc
R
W-
O/B
Y
G
W2-
Aux/ E
Y2
L
Wallplate1.6 Connect wires
Important! C wire is required and
is the power source. Without a C wire,
your thermostat will not power up.
See the C Wire Addendum document for more information.
View the Alternate Wiring videos
at wifithermostat.com/videos
1.6a Starting with the C Wire, match
the sticky tag on the wire to the
terminal labels.
1.6b Straighten wire and gently slide
into terminal hole until it clicks
into place. (If you need to
remove a wire, use a pen tip to
press the terminal release and
then pull the wire out.)
Note: Refer to the wiring picture
you took in Step 1.2.
Tip: To make it easier to slide the
wire into place, use a pen tip to
hold down the terminal release.
Note: The wiring for your
application might be different
than the wiring shown below.
Labels don’t match or have
heat pump system?
See User Guide.
Labels don’t match or have
heat pump system?
See User Guide.
1.7 Attach thermostat to wallplate Align the thermostat with
wallplate and snap into
place.
Before you beginThermostatWallplate
LEVEL
HERE
M34498A
1.8 Switch heating/cooling system ON Important! 1.8a Verify that the C wire is
connected at the thermostat
and at the heating/cooling
system.
1.8b Make sure the heating/
cooling system door is
firmly secured.
1.8c Switch power back ON for
your heating/cooling system
at the breaker box or its
power switch.
Turn over
or
M31535
1.6c In the image on the right, check
the box next to each connection.
You will use this checklist in
Step 1.9.
1.6d Verify wire is firmly secured by
gently pulling on wire.
1.6e Repeat steps a–d for all other
wires.
1.6f Push any excess wire back into
the wall opening after all wires
are installed.
Note: The L terminal on the lower right is used only for Heat Pump systems.Note: If the old thermostat for Heat Pump System has separate wires on Aux and E, use a wire nut to attach both wires to a separate wire. Slide this third wire into the W2-Aux/E terminal.Terminal release
Circuit
breaker
box
Heating/
cooling system
power switch
or
M31535
View the installation video
at wifithermostat.com/
support
You will also need:
Small screw driver
• Pen
Your home WiFi
network password
You will need your
camera to take a
picture of your old wire
connections.
Note: You will need a
picture of your wire
connections to wire
the new thermostat.
Remove jumper loop ONLY if you have both R and Rc wires.
Important!
Check the box for each wire
you connect. You will need
this information in Step 1.9.
C
K
Rc
R
W-O/B
Y
G
W2-
Aux/E
Y2
L
EXAMPLE WIRING
Yours may look different
Resideo Inc., 1985 Douglas Drive North,
Golden Valley, MN 55422
33-00268—05 M.S. Rev. 04-22 | Printed in United States
© 2022 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International, Inc.
This product is manufactured by Resideo Technologies, Inc. and its affiliates.
www.resideo.com
Electrical Ratings
Terminal Voltage (50/60Hz) Max. Current Rating
W-O/B 2030 Vac 1.0 A
W2 (Aux/E) 2030 Vac 1.0 A
Y Cooling 2030 Vac 1.0 A
Y2 Cooling 2030 Vac 1.0 A
G Fan 2030 Vac 0.5 A
33-00268-05
M38031A
HOME FAN
MODE
SETTINGS
SET TO
INDOOR
54% Humidity
FOLLOWING SCHEDULE
OUTDOOR
55% Humidity
Cool On
6:30 pm
74
°
72
°
72
°

Consulta qui gratuitamente il manuale per il Honeywell RTH9585WF1006/W. Il manuale rientra nella categoria termostato ed è stato valutato da 1 persone con una media di 7.3. Il manuale è disponibile nelle seguenti lingue: Inglese. Hai domande sul Honeywell RTH9585WF1006/W o hai bisogno di aiuto? Fai la tua domanda qui

Ho bisogno di aiuto?

Hai una domanda su Honeywell e non hai trovato la risposta nel manuale?

  • Ricevi aggiornamenti sulle soluzioni Ottieni risposte alle tue domande

Domanda e risposta

Numero di domande: 0

Generale
MarcaHoneywell
ModelloRTH9585WF1006/W
Prodottotermostati
LinguaInglese
Tipo di fileGuida Introduttiva (PDF)

Non riesci a trovare la risposta alla tua domanda nel manuale? Puoi trovare la risposta alla tua domanda nelle FAQ sul Honeywell RTH9585WF1006/W che trovi di seguito.

Qual il luogo migliore per posizionare il termostato?

Il luogo migliore per il termostato è la stanza in cui trascorri più tempo, nella maggior parte dei casi il soggiorno o la cucina. Posiziona il termostato a circa un metro e mezzo di altezza dal pavimento, fai attenzione che non sia esposto al sole e che non si trovi su una parete esterna.

Qual è la zona morta di un termostato?

Se il tuo termostato ha una zona morta, il tuo impianto è, per così dire, "in zona di riposo". Il termostato si accende solo quando, ad esempio, la differenza si discosta di più di 2˚C dalla temperatura ambiente impostata.

Qual è la temperatura ambiente ideale?

La maggior parte delle persone ritiene che la temperatura ambiente ideale sia compresa tra 19 e 22 gradi Celsius.

Il manuale del Honeywell RTH9585WF1006/W è disponibile in Italiano?

Sfortunatamente, il manuale per il Honeywell RTH9585WF1006/W non è disponibile in Italiano. Il presente manuale è disponibile in Inglese.

La tua domanda non è elencata? Fai la tua domanda qui

Nessun risultato