L2214-INS-LAB-RevD10
Features 1. Fast oral temperature measurement in approximately 10 seconds.
2. V ery sensitive unit; best for quick oral and rectal measurement.
3. Easy to read digital LCD (Liquid Crystal Display).
4. Flexiblesofttiptsnaturallyundertongueorunderarm.Won’tpokeorhurt.Flexibleprobeconforms
todifferentmouths.
5. Compact, accurate and durable LSI (Large Scale Integration) unit.
6. Ifthethermometerisinadvertentlyleftonaftertemperaturestabilization,itwillautomaticallyshutoffin
about 10 minutes.
7. Small,lightweightunit.Universaluseforthewholefamily .
8. Lesshazardousthanmercuryglassthermometers.
9. Lowbatteryindicator:whenthesymbol“ ”appears,thebatteryneedstobereplaced.
10. Thisunitiswaterproof.
Parts Description Specications Range 90°F ~ 109.3°F (32.0°C ~ 42.9°C)
< 90.0°F (32.0°C) displays Lo°F (°C)
> 109.9°F (42.9°C) displays Hi°F (°C)
Resolution 0.1° F (°C)
Accuracy ±0.2°F(93.2°Fto107.6°F)±0.4°F(otherrange)
±0.1°C(34.0°Cto42.0°C)±0.2°C(otherrange)
Display LCD (Liquid Crystal Display) 3 ½ digits
Battery (included Micro alkaline battery 192.LR41.1 5.5V
PowerConsumption 0.15milliwattsinmeasurementmode
BatteryLife >200hourscontinuousoperation
Dimensions 5.28 in x .98 in x .47 in (134 mm x 25 mm x 12 mm)
Weight Approximately0.03lb(14g)includingbattery
Beeper Approximately8secondssoundsignalwhenpeaktemperatureisreached
Memory Built-in memory enables display of previously measured value
Operation Environment T emperature 50°F ~ 95°F (10°C ~ 35°C )
Humidity 30% ~ 75% RH
Storage Environment T emperature 13°F ~ 140°F (-25°C ~ 60°C )
GuaranteeofQuality CerticationISO13485
Conformity EN12470-3, EN60601-1
ProductClassication T ypeBF equipment
Precautions — Care and Maintenance 1. Donotboiltheprobe.Cleanthethermometerbywipingitwithaclean,drycloth,anddisinfectthe
probewithisopropylalcohol.
2. Donotdropthethermometerorexposeittoheavyshock.Thethermometerisnotshockproof.
3. Donotbendorbitetheprobe.
4. Donotstorethethermometerindirectsunlight,hightemperature,highhumidity ,orinadustyenviron-
ment. Performance may be degraded.
5. Stopusingthethermometerifitoperateserraticallyorifthedisplaymalfunctions.
6. Keepthermometeroutofthereachofchildrenandalwayssupervisechildrenduringmeasurement.
7. Cleanthethermometerprobebeforestoring.
8. Donotdisassemblethethermometerexcepttoreplacethebattery .
9. Ifthethermometerhasbeenstoredatbelow-freezingtemperatures,allowittowarmnaturallytoroom
temperature before use.
10. Thermometerperformancemaybedegradedifoperatedorstoredoutsiderecommendedtemperature
andhumidityrangesshowninSpecicationssectionabove,orifthepatient’stemperatureisbelow
ambient (room) temperature.
Battery Replacement 1. Whenthesymbol“ ”appears,thebatteryneedstobereplaced.
2. Pullthebatterycoveroffinthedirectionshownbelow .
3. Ifnecessary ,useapointedobjectsuchasatoothpickorinsulated
probetogentlyprythebatterycoverandbatteryloose;avoidusing
asharpmetalobjectforthisoperation.
4. Placeanew1.55VDCbutton-sizebattery ,type192.LR41or
equivalent,inthebatterychamberwithnegativeside(–)upand
positiveside(+)down.
5. Replaceandfastenthebatterycoversecurely .
W arning: Discard the old battery carefully , out of the reach of children. Swallowing the battery
could be harmful or fatal. If the battery is inadvertently swallowed, contact a hospital immedi-
ately to have it removed. Do not dispose of the battery in a re. It may explode.
Model L2214 Digital Thermometer INSTRUCTIONS FOR USE Please read carefully before using
How to Use the Thermometer 1. DepresstheON/OFFbutton.Thedisplaywillshow or .
2. ReleasetheON/OFFbutton.ThedisplaywillshowLo°F(Lo°C)with°F(°C)ashing.
2. Disinfecttheprobewithisopropylalcohol.Seeinstructionsbelowtoplacetheprobeinanappropriate
position (oral, axillary , or rectal).
3. Oncethedegreesign(°For°C)hasstoppedashing,usuallywithin15-30seconds,thecorrecttem-
peratureisshown.Thetemperatureshowingwillnotchangeafterthe°F(°C)hasstoppedashing.
4. Thethermometerwillautomaticallyturnoffinapproximately9minutes.However ,toprolongbattery
life,itisbesttoturnthethermometeroffbypressingtheON/OFFbuttononcethetemperaturehas
been noted.
Special Features
NormalT emperature Alarm:Whenthepeaktemperaturehasregisteredandisreadytoread,analarmwill
sound.The“NormalT emperature”alarm(10beeps)willsoundforapproximately8seconds.
Fever Alarm:Whenthepeaktemperaturehasregisteredhigherthan99.5°F(37.5°C),thefeveralarm
(approximately10secondsofquickbeeps)willsound.
AutomaticLastT emperatureRecall:WhentheON/OFFbuttonispressedtoactivatethethermometer ,
display188.8willchangetoshowthelastmeasuredtemperaturevalue,thenreturnto“readytomeasure”
mode.
FahrenheitandCelsiusSwitchable:TheFahrenheitorCelsiusmodecanbeswitchedbypressingthe
ON/OFFbuttonwithintherst5seconds.
Note: Always disinfect the thermometer before use.
Note: In Step 2, if the room temperature is greater than 90.0°F (32.0°C), it will be displayed rather than
Lo°F (°C).
Note: In Step 3, you may put a sanitary plastic probe shield on the sensor tip to help prevent cross
infection and contamination. Use of the probe cover may result in a 0.2°F (0.1°C) difference from actual
temperature. Dispose of any used probe shield and store the thermometer in a safe place.
Reliable Methods to Measure Temperature Measuring Body T emperature:Changeinbodytemperatureisoneofthemostimportantindicatorsof
illness.Itisimportantthataccuratetemperaturesbetaken.Eventhoughthedigitalthermometerisused
insimilarmannertotheglassthermometer ,instructionsforuseofthisthermometermustbefollowed
closely ,andthepersontakingthetemperaturemustunderstandbodytemperature.
Body T emperature: A persons’ sbodytemperatureisusuallyseveraltenthstoonefulldegreelowerin
themorningthaninthelateafternoon.Therefore,ifyourtemperatureinthemorningis97.9°F(36.6°C),it
couldbe98.4°F(36.9°C)ormoreinthelateafternoonandstillbenormal.T odeterminewhatyournormal
bodytemperatureis,youshouldtakeyourtemperaturebothintheearlymorningandlateafternoonover
severaldays.Childrenhavethesamenormaltemperaturerangeasadults. A feverborbothchildrenand
adultsintypicallydenedasanoraltemperaturehigherthan99.5°F(37.5°C).Exercise,excessivecloth-
ing,hotbath,hotweather ,andwarmfoodanddrinkcancausemildelevationsofupto100.4°F(38°C)
inoraltemperature.Ifyoususpectoneofthesetobethecauseofanelevatedreading,eliminatethe
possiblecauseandretakethetemperatureinhalfanhour .
Oral Use
Placetheprobewellunderthepatient’stongue.Instructthepatientto
keeptheirmouthclosedwhilethethermometerismeasuring. A normal
oraltemperatureisusuallyconsideredtobebetween96.8°F–98.6°F
(36.0°C–37.5°C).
Rectal Use
Ifrectaltemperatureisrecommendedbyyourdoctor ,youmayuseaprobecover .Insertthermometer
tipintotheprobecover .Lubricatetheprobecoverwithawatersolublejellyforeasierinsertion.Donot
usepetroleumjelly .Inserttipofprobenomorethan½inchintorectum.Stopifyoumeetanyresistance.
Thesensingdeviceisontheverytipoftheprobeandthereisnoneedtoinserttheprobedeepinto
therectum.Rectaltemperatureisusuallyapproximately1.0°F–2.0°F(0.5°C–1.0°C)higherthanoral
temperature.
Axillary Use (Armpit)
Wipearmpitwithadrytowel.Placeprobeinthepatient’sarmpitandkeepthepatient’sarmpressedrmly
againsttheirside. Axillarytemperatureisusuallyapproximately1.0°F–2.0°F(0.5°C–1.0°C)lowerthan
oraltemperature.Note:Inordertoachievebetteraxillarytemperaturemeasurementresult,aminimum
measuringtimeof3-5minutesisrecommendedregardlessofthebeepsound.
Note: Children should be attended by an adult during the entire temperature recording process. After
use, the digital thermometer should be stored in a safe place, out of the reach of children. If you compare
temperatures between two thermometers, it is possible to have two different readings, even if both
thermometers are within their accuracy tolerances. Differences in how you take each reading and the
thermometer ’s tolerance range can account for nearly 0.2°F (0.1°C) variability .
Remember: Find your normal temperature and watch for changes.
Cleaning Instructions T ocleanthethermometer ,washthetipwithasolutionofmilddetergentandcoolwater .T odisinfectthe
thermometer ,wipethesensorandlowerstemwithacleanclothdippedinisopropylalcohol.
Limited warranty Thisthermometerisguaranteedagainstmanufacturer ’sdefectsundernormalhouseholduseforoneyear
fromthedateofpurchase.Followingtheinstructionscloselywillensureyearsofdependableoperation.
Ifthethermometerdoesnotfunctionproperly ,rstcheckthebatteryandreplaceitifnecessary(see
instructionsabove).RepairDepartment:1-800-672-8293.
ManufacturedforGFHealthProducts,Inc.
Atlanta, Georgia 30360
©2010GFHealthProducts,Inc.
MadeinChina
www .grahameld.com
Ho bisogno di aiuto?
Hai una domanda relativa a Lumiscope L2214 e la risposta non è nel manuale? Fai qui la tua domanda Fornisci una descrizione chiara e completa del problema e della tua domanda. Migliore sarà la descrizione del tuo problema e della domanda, più facile sarà per gli altri proprietari di Lumiscope L2214 fornirti una buona risposta.